Principles of Magnetic Circuits
The basic principles of magnetic circuits are Ohm’s law and Kirchhoff’s laws. These laws are analogous to those of the electric circuits that are identified by the same name.
Ohm’s Law
The flux of magnetic circuits is analogous to the current of electric circuits. The flux within a simple magnetic circuit is given by the ratio of the circuit’s magnetic potential divided by the reluctance of the magnetic path. Mathematically,
$$\Phi=\frac{Ni}{\mathcal{R}}\qquad (1.158)$$
This equation is Ohm’s law for magnetic circuits. In a complex electromagnetic system, the numerator of the equation should include the algebraic sum of all mmf’s in the particular loop under consideration, and the denominator should include the sum of the loop’s reluctances.
An ideal magnetic circuit (Figure 1-73(a)) can be represented in terms of either the circuit mmf (Figure 1-73(b)) or the circuit reluctance (Figure 1-73(c)). The applied mmf is $N_1i_1$, and that absorbed by the magnetic material is NI. The latter is, as per Ohm’s law, equal to $\Phi R_m$, where $\Phi$ and $R_m$ are, respectively, the flux and the reluctance of the magnetic circuit.
Figure 1-73 Magnetic circuit. (a) Elementary physical representation. (b) Equivalent circuit in terms of mmf’s. (c) Equivalent circuit in terms of reluctance.
The magnetic circuit, unlike the electric circuit, cannot be easily shorted because, as the flux increases above the knee of the magnetization curve, the permeability of the magnetic material decreases, and thus the reluctance of the magnetic path increases. Hence, there is a limit to the quantity of flux that can exist in a magnetic circuit.
The intrinsic properties of any given magnetic material are such as to limit the quantity of flux within its structure.
Exercise
The magnetic circuit shown in Figure 1-73(a) has a mean magnetic path of 0.5 m, a relative permeability of 2000, and a uniform cross-sectional area equal to 5 × 10-4 m2. The coil has 100 turns and, when connected to a 120 V, 60 Hz voltage source, draws 5 A. Determine:
a. The inductance of the coil.
$$L = \frac{\mu N^2 A}{\ell} = \frac{2 \times 10^3(4\pi \times 10^{-7})(100)^2(5 \times 10^{-4})}{0.5} = 25.13\ \text{mH}$$
b. The maximum flux through the magnetic material.
$$\phi = \frac{NI}{\ell}(\mu A) = \frac{100(5)(2 \times 10^3 \times 4\pi \times 10^{-7})(5 \times 10^{-4})\sqrt{2}}{0.5} = 1.78\ \text{mWb}$$
Kirchhoff’s Laws
Voltage Law
The KVL of magnetic circuits is similar to that of electric circuits. That is, the sum of the mmf’s along a closed loop is equal to zero. Mathematically,
$$\sum (Ni)_{\text{loop}}=0\qquad (1.159)$$
This equation is analogous to Equation (1.69), according to which the sum of the emf’s along a closed loop in an electric circuit is equal to zero.
Current Law
According to Kirchhoff’s current law, the sum of the magnetic flux in a junction is equal to zero. Mathematically,
$$\sum=\Phi_{\text{junction}}=0\qquad (1.160)$$
That is, the sum of the flux entering a magnetic junction is equal to the sum of the flux leaving the junction.
For magnetic circuit calculations, take into consideration the leakage flux, the stacking factor, and the fringing of the flux through the circuit’s air gaps.
Stacking Factor
The effective cross-sectional area of a magnetic core is less than the actual cross-sectional area because of the insulation on the surface of the laminations. The reduction in the actual area is accounted for by using what is called a stacking factor. The value of the stacking factor ranges between 0.85 and 0.95, depending on the thickness of the laminations and on the amount of their surface insulation.
Fringing
The spreading out of the flux around the edges of an air gap (Figure 1-50) is called fringing or diverging of the flux. In calculating the flux density through a short air gap, fringing is accounted for by increasing the given cross-sectional area of the air gap as shown below.
$$\text{Effective cross-sectional area}=(m+l_g)(n+l_g)\qquad (1.161)$$
where m and n are the dimensions of the magnetic core perpendicular to the flux lines and $l_g$ is the length of the air gap.
Leakage Flux
The leakage flux is relatively small, owing to its large reluctance path. Thus, it is normally neglected in magnetic circuit calculations. In the analysis of transformers and electric machines, however, the effects of the leakage flux are included in their equivalent electric circuits.
Example 1-25
In the circuit shown in Figure 1-74(a), $l_g$ and $l_m$ represent, respectively, the length of the air gap and the total length of the mean magnetic path. Determine:
a. An expression for the total reluctance.
b. The length of the air gap that will absorb one-half of the applied mmf.

Figure 1-74 Magnetic Material and Equivalent Circuit
Solution
The equivalent circuit is shown in Figure 1-74(b).
a. The total reluctance is the sum of the reluctance of the magnetic material and that of the air gap. Thus,
$$\mathcal{R}_T = \mathcal{R}_m + \mathcal{R}_{\text{air gap}} = \frac{l_m}{\mu_A} + \frac{2l_g}{\mu_0 A}$$
$$\mathcal{R}_T = \frac{1}{\mu_0 A}\left(\frac{l_m}{\mu_r} + 2l_g\right)$$
Where $l_g$ is the length of each air gap.
b. From the equivalent circuit, the reluctances are in series. For one-half of the input mmf to be absorbed by the air gap, the reluctances of the magnetic material should be equal to that of the air gap. Thus,
$$\frac{l_m}{\mu} = \frac{2l_g}{\mu_0}$$
From which
$$l_g = \frac{l_m}{2\mu_r}$$
Example 1-26
For the schematic shown in Figure 1-75(a), draw the equivalent circuit in terms of:
a. mmf’s
b. Reluctances.

Figure 1-75 Magnetic Material and Circuit Diagram
Solution
a. The equivalent circuit, in terms of mmf’s, is shown in Figure 1-75(b). The mmf’s in the air gap and in the other magnetic paths are identified with the same subscripts as the mean magnetic lengths. Applying KVL, we have
$$Ni = (Ni)_a + (Ni)_c + (Ni)_g$$
Or
$$Ni = (Ni)_a + (Ni)_b$$
It should be noted that, as in electric circuits, magnetic circuits and magnetic potentials across parallel branches of reluctances are equal.
b. The equivalent circuit with the various reluctances is shown in Figure 1-75(c). Applying Ohm’s law for magnetic circuits, we obtain
$$\Phi_1 = \frac{Ni}{\mathcal{R}_a + \mathcal{R}_b // (\mathcal{R}_c + \mathcal{R}_g)}$$
Applying the current-divider concept, we find
$$\Phi_3 = \Phi_1\left(\frac{\mathcal{R}_b}{\mathcal{R}_b + \mathcal{R}_c + \mathcal{R}_g}\right)$$
And
$$\Phi_2 = \Phi_1\left(\frac{\mathcal{R}_c + \mathcal{R}_g}{\mathcal{R}_b + \mathcal{R}_c + \mathcal{R}_g}\right)$$
Graphical Analysis of Electromagnetic Circuits
In calculations involving magnetic circuits that include air gaps, the magnetization and permeability of the materials are usually unknown. The level of magnetization and the corresponding permeability are factors of the basic magnetic circuit equations. In setting up these equations, often there are more unknowns than equations. This is similar to the analysis of electronic circuits (transistor or diode) where the voltage and current of electronic devices are unknown.
One way to solve these problems is by trial and error, according to which an unknown parameter is assumed. If this assumed parameter satisfies the governing magnetic circuit equations, it is an acceptable solution. If it does not, then another value is assumed until a satisfactory solution is found.
A more effective method is to use a graphical solution. With this technique, the given B-H characteristic is changed to its equivalent $\Phi-Ni$ characteristic and the flux of the magnetic circuit is found as a function of the magnetomotive forces within a closed loop.
The resulting equation is drawn on the same coordinate system as the $\Phi-Ni$ characteristic. The point of intersection of the two characteristics gives the actual flux and the magnetic potential drop within the magnetic material.
For a demonstration, consider the simple magnetic circuit of Figure 1-76(a). Its B-H characteristic is shown in Figure 1-76(b). The lengths of the magnetic material $(l_m)$ and of the air gap $(l_g)$ as well as their effective areas ($A_m$ and $A_g$) are known.

Figure 1-76 Graphical solution of magnetic circuits: (a) Simple magnetic circuit. (b) B-H and $\Phi-Ni$ characteristic. (c) Equivalent circuit.
In order to find the flux through the magnetic material, proceed as follows:
Steps
1. Draw the $\Phi-(Ni)_m$ characteristic.
Change the coordinates of the B-H characteristic to its equivalent $\Phi-(Ni)_m$ characteristic ($\Phi=BA$ and $(Ni)_m=H_m\times l_m$).
2. Write the governing equations (Figure 1-76(c)).
$$(Ni)_s=(Ni)_m+(Ni)_g\qquad (1.162)$$
$$(Ni)_g=\Phi\mathcal{R}_g\qquad (1.163)$$
where $(Ni)_s$, $(Ni)_m$, $(Ni)_g$ and represent the magnetic potentials of source, magnetic material, and air gap, respectively.
3. Draw the load-line equation.
From Eqs. (1.162) and (1.163) we obtain
$$(Ni)_s=(Ni)_m+\Phi\mathcal{R}_g\qquad (1.164)$$
from which
$$\Phi=\frac{(Ni)_m}{\mathcal{R}_g}+\frac{(Ni)_s}{\mathcal{R}_g}\qquad (1.165)$$
Equation (1.165) is of the slope (m)-intercept (b) form $(y = mx + b)$. Its intercepts are
$$y\text{-intercept}\quad \Phi = \frac{(Ni)_s}{\mathcal{R}_g}, \qquad x\text{-intercept} = (Ni)_s$$
Since the intercepts are known, the equation is drawn as shown in Figure 1-76(b). Equation (1.165) is known as the load-line equation. Its intersection with the $\Phi - Ni characteristic gives the operating point, which is designated by the letter Q. The operating point gives the actual flux, and the mmf drop within the magnetic material and through the air gap, as shown in Figure 1-76(b).
Exercise
The coordinates of the B-H characteristic of the magnetic material shown in Figure 1-77 are as follows:
|
B (T) |
0.10 |
0.45 |
0.78 |
0.96 |
1.08 |
|
H (A/m) |
50 |
150 |
350 |
800 |
1440 |

Figure 1-77 Magnetic Material
The mean length of the magnetic path is 0.75 mm, and the effective area of the magnetic material and that of the air gap are 1.1 × 10-3 m2 and 1.2 × 10-3 m2, respectively. For an air-gap length of 0.60 mm, determine the flux density in the magnetic material.
Solution
|
B |
0.1 |
0.45 |
0.78 |
0.96 |
1.08 |
|
ϕ = BA |
0.11 |
0.495 |
0.85 |
1.056 |
1.18 |
|
NI = Hℓ |
37.5 |
112.9 |
262.5 |
600 |
1080 |
|
H |
50 |
150 |
350 |
800 |
1440 |
y-intercept:
$$\frac{(NI)_s}{R} = \frac{(NI)_s\mu_0 A}{\ell_g}$$
$$= \frac{(800)(4\pi \times 10^{-7})(1.2 \times 10^{-3})}{0.6 \times 10^{-3}} = 2.01\ \text{mWb}$$
x-intercept:
$$(NI)_s = 800$$
Graphically, the coordinates of Q are
$$\phi = 0.98\ \text{mWb}, \qquad (NI)_m = 430\ \text{A}$$
$$B = \frac{0.98 \times 10^{-3}}{1.1 \times 10^{-3}} \approx 0.90\ \text{T}$$

Figure 1-78 Graphical Representation of Flux Density