Magnetic Losses


Basic Electromagnetic Concepts


Magnetic losses can be separated into eddy-current losses and hysteresis losses. The total magnetic losses (Pm) of a coil are given by

$$P_m = P_e + P_h \qquad (1.166)$$

where Pe and Ph represent, respectively, eddy-current and hysteresis losses. Eddy currents are produced within the magnetic material because of the alternating nature of the flux, which in turn is produced by the winding’s ac current. When the magnetic material has infinite resistance (zero conductivity), however, there will not be any eddy-current losses.

Hysteresis represents the friction among the walls of the magnetic domains. The magnetic domains are constantly being reoriented because of the alternating nature of the applied field.

Magnetic losses are also referred to as excitation losses or open-circuit losses.

Eddy-Current Losses

The voltage applied to a coil wound around a toroidal magnetic material will be accompanied, as can be predicted from the induction principle, by a flux. Mathematically,

$$\upsilon = -N\frac{d\Phi}{dt} \qquad (1.167)$$

For operations along the linear section of the magnetization characteristic, the flux, according to Ohm’s law for magnetic circuits, is proportional to the current. That is, for a linear change in the flux there will be a linear change in the current. Using mathematical symbols:

$$\Phi \propto i \qquad (1.168)$$

According to Lenz’s law, the flux within the magnetic material will induce opposing voltages that produce circular currents ( Ie , eddy currents). As shown in Figure 1-79, these induced currents flow around the flux and produce eddy-current loss.

An illustration of eddy currents. (a) Nonlaminated core. (b) Laminated core (notice the relative reduction in the eddy currents).

Figure 1-79 An illustration of eddy currents. (a) Nonlaminated core. (b) Laminated core (notice the relative reduction in the eddy currents).

The eddy-current loss is proportional to eddy current squared. That is,

$$P_e \propto I_e^2 \qquad (1.169)$$

In terms of the applied voltage, the last expression becomes

$$P_{e}=K_{1}V^2 \qquad (1.170)$$

where V is the effective value of the applied voltage and K1 is a constant of proportionality. This constant is directly proportional to the volume of the material and inversely proportional to its resistivity.

Substituting for the voltage its equivalent expression from Equation (1.148), we obtain

$$P_e = K_2(f\phi)^2 \qquad (1.171)$$

The constant of proportionality K2 is directly proportional to K1 and to the square of the number of turns of the coil.

Eddy-current losses can be reduced by increasing the resistance to the flow of eddy currents and/or by decreasing the magnitude of the flux.

Resistance to the flow of eddy currents (Re) can be increased by decreasing the thickness of the laminations and by increasing their surface insulation.

For a given coil voltage, the flux can be reduced by increasing the number of winding turns.

Hysteresis Losses

Hysteresis losses are heat losses due to the friction between magnetic domains. Each time the input voltage changes polarity, the magnetic field within the core of the coil also changes polarity. Thus, the flux—or the lines of force—change direction. The consequent continuous alignment and realignment of the magnetic domains in the direction of the alternating flux produce friction, which manifests itself as heat within the material.

Hysteresis loss (Ph) is related to the flux of the core and to the frequency (f) of the voltage source by

$$P_h \propto f\Phi^h \qquad (1.172)$$

where h is a constant characteristic of the material. Its usual range is from 1.4 to 2.5.

From Equations (1.148) and (1.172), we obtain

$$P_h \propto f\left(\frac{V}{f}\right)^h \qquad (1.173)$$

From the above,

$$P_h = K_3\frac{V^h}{f^{h-1}} \qquad (1.174)$$

The constant of proportionality K3 is directly proportional to the volume of the magnetic material under consideration.

Etymologically, hysteresis is a Greek word that means lagging. In fact, owing to hysteresis, the induced emf is not at 90o to the flux but lags it by $\left(90^\circ + \theta_h\right)$, where $\theta_h$ is due to the hysteresis phenomenon (see Figure 1-80). This deviation in the phase angle is used to advantage in the production of torque in so-called hysteresis motors.

Effect of hysteresis on the phase angle between flux and emf.

Figure 1-80 Effect of hysteresis on the phase angle between flux and emf.

The hysteresis losses of a magnetic material can also be evaluated from the area of its hysteresis loop as follows (see Figure 1-81):

$$\text{Area of hysteresis loop} = \int H\,dB \qquad (1.175)$$

Hysteresis loop.

Figure 1-81 Hysteresis loop.

Substituting the values

$$H = \frac{Ni}{l}$$

And

$$dB = \frac{d\Phi}{A} = -\frac{\upsilon}{AN}\,dt$$

we obtain

$$\text{Area of hysteresis loop} = -\frac{1}{Al}\int \upsilon i\,dt \qquad (1.76)$$

As seen from the above, the area of a hysteresis loop is equal to the energy dissipated in the material per cycle per unit volume due to the hysteresis phenomenon.

An alternative method of evaluating the hysteresis losses of a material subjected to a cyclic variation of its magnetizing force is to measure the area of the hysteresis loop in proper units and to multiply that area by the period of the magnetizing force expressed in seconds.

For example, if the cyclic variation of the magnetizing force is 60 times per second and the area of the resulting hysteresis loop has 25 squares, the perpendicular sides of which are equal to 0.15 T and 2 A/m, respectively, the hysteresis losses are

$$25(0.15)(2)(60) = 450\ \text{W/m}^3$$

Example 1-27

a. Figure 1-82 shows a section of an underground, three-phase, three-single-conductor, 4.16 kV power distribution network. The contractor mistakenly installed steel instead of plastic elbows as adaptors. As a result, the cables were damaged during the plant’s operation, owing to induction currents. Explain the underlying principles and the nature of magnetic losses.

Three-phase, three-single-conductor, power distribution.

Figure 1-82 Three-phase, three-single-conductor, power distribution.

As per industrial practices the PVC conduit is used for exposed cable installations (such as going from the secondary transformer terminals to the underground cable distribution), while the PV duct is used only in concealed underground cable distribution. Both the conduit and the duct are made from plastic material, but the conduit is much more rugged than the duct.

b. Prove that no induction currents are induced in steel conduits through which one three-conductor cable is installed.

Solution

a. Owing to Ohm’s law in magnetic circuits $(\phi = Ni/\mathcal{R})$, the conductor’s current produced flux, which according to the “right-hand rule,” encircled the area outside the conductor’s current. As a result, flux was induced in the galvanized steel elbows.

The sinusoidal variation of the steel elbow’s flux produced eddy currents and continuous realignment of the material’s magnetic domains. According to Lenz’s law, eddy currents represent the natural reaction of the material to oppose the induced flux. The realignment of the magnetic domains is a natural tendency of the basic building blocks of magnetism to follow the direction of the external field.

Eddy currents produced eddy-current losses $(P_e \propto V^2)$ and the alternating realignment of the magnetic domains produced hysteresis losses $(P_h \propto f\phi^{1.6})$. This resulted in overheating of the steel elbows, which led to the melting of the conductor’s insulation, generation of sparks, and electrical shorting of the multiconductor distribution. Thus, owing to the induction principle, the cables were damaged and the plant’s production was interrupted for the time necessary to identify the problem, remove the steel elbows, and purchase and install new cables.

b. Induction currents are not induced in a steel conduit through which a three-conductor cable (phases A, B, and C) passes because the net induced flux is theoretically equal to zero. The proof of this is as follows:

The resultant flux $(\phi_r)$ induced in the steel conduit is due to the flux of three-phase currents. That is,

$$\phi_r = \phi_A + \phi_B + \phi_C$$

where $\phi_{A}$, $\phi_{B}$ , $\phi_{C}$ and represent the flux produced by the individual phase currents. 

From the theory of three-phase systems, each current, or flux, is equal in magnitude to the others and is displaced 120 degrees from the others in phase. Thus, designating the rms value of the flux of the one-phase conductor with $\phi$, we have

$$\phi_r = \phi\left(1\angle 0^\circ + 1\angle 120^\circ + 1\angle -120^\circ\right) = 0$$

In actual cases, some flux (which has negligible heating effects) will be induced, owing to imperfect symmetry in the phase conductor’s spacing relative to the steel conduit.

This industrial problem occurred in a factory in the Southwestern United States in August 1981. Damage was estimated at several hundred thousand dollars. It is astonishing that such a faulty installation took place, considering that (according to internal company memos) the consultants who designed the electrical distribution system, as well as the plant’s electrical engineers, were very much aware of the induction problems associated with single-conductor distribution. What is more, the construction manager who supervised the installation was an experienced mechanical engineer.

Example 1-28

A firm that manufactures transformers requires magnetic materials that have a relative permeability equal to 100. A salesman of magnetic materials claims and demonstrates in the lab that his company’s product has a permeability equal to 100. After testing the proposed material, however, the manufacturing firm’s engineer rejects it. Give two possible technical reasons for his decision.

Solution

The permeability of a material has meaning only when the flux density at which it is measured is specified. As shown in Figure 1-61, each magnetic material has a wide range of permeabilities. The engineer may have rejected the materials because, at the level of flux density he or she was interested in, the permeability was not 100.

A second reason may have been that the losses of the proposed materials were too high. Additional reasons for the engineer’s rejection of the proposed material may have been the unacceptable change in its permeability with time (disaccommodation factor) at high temperatures. The cost of the material is also of paramount importance.

This example demonstrates the various interrelated factors that tend to be considered when a decision is to be made in selecting and/or designing a product. The phrasing of the specifications, or the description of the problem, is also important. In the above example, the manufacturer’s requirements were not explicitly stated; an experienced salesperson should have known the implied restrictions when dealing with the properties and characteristics of magnetic materials.